位置:EVAL-AD4130-8 > EVAL-AD4130-8詳情
EVAL-AD4130-8中文資料
EVAL-AD4130-8數(shù)據(jù)手冊(cè)規(guī)格書PDF詳情
GENERAL DESCRIPTION
The AD4130-8 is an ultra low power, high precision, measurement
solution for low bandwidth battery operated applications. The fully
integrated analog front end (AFE) includes a multiplexer for up
to 16 single-ended or eight differential inputs, programmable gain
amplifier (PGA), 24-bit sigma-delta (Σ-Δ) analog-to-digital converter
(ADC), on-chip reference and oscillator, selectable filter options,
smart sequencer, sensor biasing and excitation options, diagnostics,
and newly added features to improve the battery-operated
lifetime (more than 5 years on a coin cell), that is, a first in, first out
(FIFO) buffer and duty cycling.
The AD4130-8 allows users to measure low frequency signals
with a current consumption of 28.5 μA (gain = 1) and 32.5 μA
(gain = 128) while continuously converting, and even lower average
currents when using one of the duty cycling options. The AD4130-8
can be configured to have 8 differential inputs or 16 single-ended or
pseudo differential inputs, which connect to a crosspoint multiplexer,
where any input pair can become a measurement channel input
to the PGA and ADC.
The AD4130-8 is designed to allow the user to operate from a
single analog supply voltage from 1.71 V to 3.6 V. In battery
applications, operation as low as 1.71 V can extend the system
lifetime as the AFE can continue its operation, even as the battery
voltage dissipates. The digital supply can be separate and range
from 1.65 V to 3.6 V.
Together with the reduced current consumption, the integration of
an on-chip FIFO buffer can be used in tandem with the smart
sequencer, to enable the AD4130-8 to become an autonomous
measurement system, which allows the microcontroller to sleep for
extended periods.
Intelligent interrupt functionality gives the user a greater confidence
in both error detection and safety. The user can enable an interrupt
signal to trigger when the samples in the FIFO reach a predefined
value or when a user programmable threshold is exceeded.
The following key analog functions are offered on the AD4130-8
to allow simple and effective connection to transducers used for
measuring temperature, load, and pressure:
? PGA. Due to the programmable gain (from 1 to 128) and the
high input impedance with low input current, the PGA allows
direct interfacing to transducers with low output amplitudes like
resistive bridges, thermocouples, and resistance temperature
detectors (RTDs).
? The capacitive PGA allows full common-mode input range, giving
designers greater margin for widely varying input common
modes. A wider common-mode input range improves the overall
resolution and is highly effective in ratio metric measurements.
? Low drift precision current sources. The IEXC0 and IEXC1 current
source can be used to excite 2?, 3?, and 4?wire RTDs.
Excitation current output options include 100 nA, 10 μA, 20 μA,
50 μA, 100 μA, 150 μA, and 200 μA.
? The low-side power switch (PDSW) can be used to power down
bridge sensors between conversions. The PDSW can be controlled
within the sequencer on a per channel basis, allowing
optimum timing and energy savings in the overall system. The
PDSW can also allow higher powered analog sensors to be used
in a low power system.
? Voltage bias for thermocouples (the VBIAS source sets the
common-mode voltage of a channel to AVDD/2).
? The smart sequencer allows the conversion of each enabled
preconfigured channel in a predetermined order, allowing a mix
of transducer, system checks and diagnostic measurements to
be interleaved. The sequencer eliminates need for repetitive
serial interface communication with the device. Sixteen channels
can be configured in the sequence, each of them selecting from
eight predefined ADC setups that allow selection of gain, filter
type, output data rate, buffering, timing, and reference source.
High levels of integrated front-end functionality coupled with small
package options allow smaller end solutions. For example, the
AD4130-8 integrates a low thermal drift band gap reference in
addition to accepting an external differential reference, which can
be internally buffered.
In safety critical applications the AD4130-8 includes diagnostic
functionality such as open wire detection via burnout currents,
internal temperature sensor, reference detection, and analog input
overvoltage and undervoltage detection. Added diagnostics are
included on the digital interface like cyclic redundancy check (CRC)
and serial interface checks for a robust communication link.
FEATURES
? Ultralow current consumption (typical):
? 32 μA: continuous conversion mode (gain = 128)
? 5 μA: duty cycling mode (ratio = 1/16)
? 0.5 μA: standby mode
? 0.1 μA: power-down mode
? Built-in features for system level power savings:
? Current saving duty cycle ratio: 1/4 or 1/16
? Smart sequencer and per channel configuration minimizes host processor load
? Deep embedded FIFO minimizes host processor load (depth of 256 samples)
? Autonomous FIFO interrupt functionality, threshold detection
? Single supply as low as 1.71 V increasing battery length
? RMS noise: 25 nV rms at 1.17 SPS (gain = 128) – 48 nV/√Hz
? Up to 22 noise free bits (gain = 1)
? Output data rate: 1.17 SPS to 2.4 kSPS
? Operates from 1.71 V to 3.6 V single supply or ±1.8 V split supplies
? Band gap reference with 15 ppm/°C maximum drift
? PGA with rail-to-rail analog input
? Adaptable sensor interfacing functionality:
? Matched programmable excitation currents for RTDs
? On-chip bias voltage generator for thermocouples
? Low-side power switch for bridge transducers
? Sensor open wire detection
? Internal temperature sensor and oscillator
? Self and system calibration
? Flexible filter options
? Simultaneous 50 Hz/60 Hz rejection (on selected filter options)
? General-purpose outputs
? Diagnostic functionality
? Crosspoint multiplexed inputs
? 8 differential/16 pseudo differential inputs
? 5 MHz SPI (3-wire or 4-wire)
? Available in 35-ball, 2.74 mm × 3.6 mm WLCSP
? Temperature range: ?40°C to +105°C
APPLICATIONS
? Smart transmitters
? Wireless battery and harvester powered sensor nodes
? Portable instrumentation
? Temperature measurement: thermocouple, RTD, thermistors
? Pressure measurement: bridge transducers
? Healthcare and wearables
供應(yīng)商 | 型號(hào) | 品牌 | 批號(hào) | 封裝 | 庫(kù)存 | 備注 | 價(jià)格 |
---|---|---|---|---|---|---|---|
AD |
23+ |
121 |
|||||
AD |
23+ |
原廠原包 |
19960 |
只做進(jìn)口原裝 終端工廠免費(fèi)送樣 |
|||
AD |
24+ |
9000 |
5000 |
原裝現(xiàn)貨 |
|||
ADI/亞德諾 |
25+ |
20000 |
原裝現(xiàn)貨,可追溯原廠渠道 |
||||
ADI/亞德諾 |
23+ |
EB/PCB |
3000 |
只做原裝正品,假一賠十 |
|||
ADI/亞德諾 |
20+ |
EvaluationBoard |
33680 |
ADI全新原裝-可開原型號(hào)增稅票 |
|||
ADI/亞德諾 |
22+ |
66900 |
原封裝 |
||||
ADI/亞德諾 |
25+ |
原封裝 |
8800 |
公司只做原裝,詳情請(qǐng)咨詢 |
|||
ADI/亞德諾 |
2511 |
原封裝 |
66900 |
電子元器件采購(gòu)降本 30%!盈慧通原廠直采,砍掉中間差價(jià) |
|||
Analog Devices Inc |
22+ |
NA |
500000 |
萬(wàn)三科技,秉承原裝,購(gòu)芯無(wú)憂 |
EVAL-AD4130-8 資料下載更多...
EVAL-AD4130-8 芯片相關(guān)型號(hào)
- 05N03LS5
- 2SA1011
- BD9G500EFJ-LA
- EVAL-AD4030-24FMCZ
- EVAL-AD4030-24-KTZ
- EVAL-AD4116ASDZ
- EVAL-AD4134FMCZ
- KBP3005G
- LCMXO2-256HC-5UMG64I
- MURS310CG
- PKGS-00LC
- PKGS-00ME
- PKGS-00RA
- SF-1206HH25M-2
- SF-1206HH30M-2
- SF-1206HHXXM
- SF20W1000ATLQ
- SF20W1000BTLQ
- SF20W1000CTLQ
- SFR10S40ADTR
- SFT-142
- SI9803DY-T1-E3
- TL431ACD
- TLV9004IDYYR
- TLV9004QPWRQ1
Datasheet數(shù)據(jù)表PDF頁(yè)碼索引
- P1
- P2
- P3
- P4
- P5
- P6
- P7
- P8
- P9
- P10
- P11
- P12
- P13
- P14
- P15
- P16
- P17
- P18
- P19
- P20
- P21
- P22
- P23
- P24
- P25
- P26
- P27
- P28
- P29
- P30
- P31
- P32
- P33
- P34
- P35
- P36
- P37
- P38
- P39
- P40
- P41
- P42
- P43
- P44
- P45
- P46
- P47
- P48
- P49
- P50
- P51
- P52
- P53
- P54
- P55
- P56
- P57
- P58
- P59
- P60
- P61
- P62
- P63
- P64
- P65
- P66
- P67
- P68
- P69
- P70
- P71
- P72
- P73
- P74
- P75
- P76
- P77
- P78
- P79
- P80
- P81
- P82
- P83
- P84
- P85
- P86
- P87
- P88
- P89
- P90
- P91
- P92
- P93
- P94
- P95
- P96
- P97
- P98
- P99
- P100
- P101
- P102
Analog Devices 亞德諾半導(dǎo)體技術(shù)有限公司
(Analog Devices,簡(jiǎn)稱ADI)成立于1965年,總部位于美國(guó)馬薩諸塞州諾丁漢,是全球領(lǐng)先的高性能模擬、混合信號(hào)和數(shù)字信號(hào)處理集成電路(IC)設(shè)計(jì)與制造公司。ADI致力于為各種應(yīng)用提供創(chuàng)新的解決方案,涵蓋通信、工業(yè)、汽車、醫(yī)療、消費(fèi)電子和數(shù)據(jù)中心等多個(gè)領(lǐng)域。 公司以其強(qiáng)大的研發(fā)實(shí)力和專業(yè)技術(shù)著稱,擁有廣泛的產(chǎn)品組合,包括放大器、轉(zhuǎn)換器、傳感器和處理器等,能夠滿足客戶在信號(hào)處理和控制方面的需求。ADI的產(chǎn)品被廣泛應(yīng)用于數(shù)據(jù)測(cè)量、無(wú)線通信、音頻處理、視頻監(jiān)控以及自動(dòng)化和控制系統(tǒng)等領(lǐng)域。 模擬器件公司始終致力于推動(dòng)技術(shù)創(chuàng)新,憑借強(qiáng)大的科技實(shí)力,為客戶提供高效、可靠的解決方案,幫助他們提高